Fixed Type Gas Transmitter

TI-CD-200

TI-CD-200 Integrated point-type gas detector can satisfy the sound and light alarm prompt in the gas detection field, and real-time display the field gas concentration. The debugging adopts infrared remote control, and the parameters can be set without opening the cover. TI-CD-200 integrated point-type gas detector can transform the leakage gas concentration signal in air into electrical signal for long-distance transmission.

  • High Accuracy & Reliable Performance – Precise measurement for critical industrial applications.
  • Real-Time Monitoring – Continuous data for better process control and quick decision-making.
  • Low Maintenance – Designed for long-term operation with minimal servicing.
  • Industrial-Grade Durability – Built to perform in harsh environments like dust, heat, and vibration.
Still Confused What to Buy?

Need help deciding? Download resources to know more about the product.

  • HD display
  • Multiple alarm
  • Smart sensors, modular design, convenient maintenance
  • One-click restore factory Settings to prevent wrong operation
  • 4~ 20 mA and RS485 output signal
  • The infrared remote control, dangerous places to avoid open operation
  • Power Plants – Boiler flue gas me dust emission monitoring.
  • Coal Gasification Units – Gas line me dust concentration monitoring.
  • Cement Plants – Bag filter / stack dust emission monitoring.
  • Steel Industry – Process ducts aur emission stacks me dust monitoring.
  • Chemical Plants – Process gas lines me particulate monitoring.
  • Powder Material Recovery Systems – Pneumatic conveying lines me dust detection
  • Fixed Pollution Sources – Industrial stack emission monitoring.
  • Fuel Boilers – Coal / biomass boiler exhaust me dust concentration monitoring.
  • Process Transport Lines – Dust carrying pipelines me dust quantity monitoring.
  • Incinerators – Waste burning exhaust gas dust monitoring.
  • Detection Gas: Combustible gas and toxic gas
  • Sensor Types Available: Catalytic combustion, electrochemical, infrared, semiconductor, MOS and PID sensors
  • Sampling Mode: Natural diffusion
  • Detection Range: 0–100% LEL, 0–**** ppm, 0–30% Vol (depending on the gas being detected)
  • Resolution: 1% LEL, 1 ppm / 0.1 ppm, 0.1% (depending on the gas type)
  • Accuracy: ≤ ±2% F.S.
  • Response Time: < 30 seconds
  • Display Screen: LCD display showing gas concentration, menu and alarm status
  • Output Signals: 4–20 mA analog output, RS485 communication and relay output
  • Alarm Modes: Audible-visual alarm, vibration alarm and relay output alarm
  • Operating Conditions: Temperature -20°C to 50°C, Humidity <95% RH (non-condensing)
  • Power Supply: DC 24 V, Power consumption <3 W
  • Ingress Protection: IP66
  • Installation Options: Wall mounted or pipe type installation
  • Electrical Interface: G1/2
  • Dimensions: 185 × 142 × 83 mm (L × W × H)
  • Weight: 1.5 kg
  • Service Life: 2–3 years depending on operating environment conditions

    Watch Our Product in Action

    Comprehensive Services Using This Product

    From installation to ongoing support, we’re with you every step of the way.

    What Customers Say About Us

    Trusted Engineering Support

    The team provided clear technical guidance and practical solutions. Execution was smooth and well coordinated throughout.

    Mr. Vivek Nair
    Mr. Vivek NairGeneral Manager – Operations, Cement Industry
    Dependable Technical Partner

    Their approach was systematic and aligned with our plant needs. Overall experience with product and service has been positive.

    Ms. Kavita Rao
    Ms. Kavita RaoSenior Manager – Maintenance, Steel Sector
    Application-Focused Solutions

    They understood our process conditions before recommending equipment. Support during installation was handled professionally.

    Mr. Rohan Mehta
    Mr. Rohan MehtaProject Lead – Power Plant
    Consistent Service Delivery

    Product performance has been stable in regular operations. The support team responds in a timely manner.

    Mr. Anil Deshmukh
    Mr. Anil DeshmukhInstrumentation Head, Process Manufacturing

    Insights & News

    The Role of Calibration in Quality Assurance
    Understand why regular calibration of instruments is vital for maintaining accuracy, safety, and consistency in industrial processes—and how TIPL’s NABL-accredited labs ensure precise performance across sectors.
    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions About This Product

    The TI-CD-200 is a fixed gas detection device used to monitor combustible and toxic gases in real time. It detects gas concentration in the environment and sends signals to monitoring or alarm systems to ensure safety in industrial areas.
    The transmitter can detect combustible gases and toxic gases, depending on the sensor type installed.
    The TI-CD-200 uses natural diffusion sampling, meaning gases naturally diffuse into the sensor without the need for an external pump.
    The system provides audible and visual alarms and supports relay output alarms when gas concentration exceeds preset limits.
    The typical response time is less than 30 seconds.
    The device operates within -20°C to +50°C environmental temperature.